919575122819
SYRINGE PUMP

CREST SYRINGE PUMP FROM PLENUMTEK

Description

Product Details: Dimension 130 mm (W) x 183mm (L) x 115mm (H) Power Source 110/220 VCA (+/-20%), 50/60 Hz, 12 VA Operating Temp 05 deg - 40 deg C Weight 1.8 Kgs Display Size & Type 135mm x 21mm EBTN LCD Display Relative Humidity 15 to 90% (no condensation) Atmospheric Pressure 70 to 106 Kpa Battery 4.8 Rechargeable NiMh Capacity minimum 4hrs @ 5ml/hr Recharging time 16 hrs Syringe Size 10 ml-10 ml, 10 ml-60 ml, 60 ml-100 ml, 10 ml-10 ml, 10 ml-60 ml, 60 ml-100 ml Number of Syringes 1.0 Physical Specification: Product Type: Front Loading Syringe Infusion pump Pumping Mechanism: Lead Screw Mechanism Parameters Diplayed: Syringe size, Syringe Brand, Set Flow Rate Infused Volume, Occlusion level, Battery life Alarms & Indicators Keypad: Capacitive touch screen keypad Fixation: Allows Horizontal and Vertical Mounting Stackability: For interlocking of two or more units Basic Infusion Controls: Syringe Capacity: 5,10,20,30,50/60 and 100 CC Auto Detection Syringe Brands: Dispovan, BBraun Perfusor, BD Precise, Platipak Romson & Sisco (Provision add 12 more brands) Flow Rate: 0.1 to 1200 ml/hr (increment in step of 0.1ml/hr Facility for Online titration Purge: Upto 1200 ml/hr Bolus Rate: Upto 1200 ml/hr Bolus Volume: Settable (pre-set) KVO/KOR: 1% of the set rate or minimum of 0.1 ml/hr Mechanical Accuracy: +/- 1% Overall Accuracy: +/- 2% (Measured Time > 1Hr, min 0.2 ml excluding syringe tolerance) (Measured as per IEC 60601-2-24) Pressure Management: Pressure Limits: Low 0.4 kg/cm2 (300 mmHg), Mid 0.8 kg/cm2 (600 mmHg), High 1.2 kg/cm2 (900 mmHg) Tolerance: +/- 20% Anti-bolus System: Reduces significantly bolus after occusion release (measured as per IEC 60601-2-24) Pre Alarms/Alarms/Security Features: Alarms: All the alarms are expressed by means of flashing message/symbol on the display and sound beep Syringe Detection: Syringe Dislocated, Drive Disengaged, Patient Line Disconnection, Plunger Disengaged Device Control: No Mains, Battery pre-alarm & Alarm, Idle Technical Malfunction Infusion Control: Occlusion, Infusion End pre-alarm & Alarm KVO/KOR, Syringe Empty Standard Accessories: Unit with pole clamp, power cord & operating manual Optional Feature: Power Source: External Power 12 VDC converter (For Ambulatory supply) Battery Life: Upgradable to 5 hr / 10 hr @ 5 ml/hr Stackability: Multiple inputs AC cord for up to 8 pumps Communication: RS232 port Other: Nurse call attachment Quality Standard: Electrical Safety: Class II, Type CF Additional Information: Item Code: CREST

products-and-services