919575122819
SYRU 4004

SYRU 4004 Syringe Pump AKAS

Description

AKAS SYRU 4004 is a front loading syringe pump which is compact, light and rugged. Designed in an elegant fashion it stands out in your ICU. It works accurately for adult, pediatric and neonatal patients with laminar drug flow improving the patient care when drugs with short half-life is administered. Concentrated medicines need to be injected continuously as well as slowly into the patient. Syringe pumps are highly helpful under such situations as they can be programmed to deliver a specified quantity of drug through the vein at a predetermined rate. AKAS TERUMAX Syringe Pump can be used in Adult, Pediatric and Neonatal Patients Features Suitable for Cardiothoracic Patients Rugged and Strong design for rough use Compact (2.4 ltr) & Light weight(1.75kg) 0.1 to 1200ml/hr flow rate Long battery back up (up to 10 Hrs ) Dosage ramp up and tapper down function Custom programmable mode to accept any brand of syringe Auto / Purge bolus facility Multiple safety alarm facility Inline program during infusion Technical Specifications Power Supply (I/P) : AC 220V to 240V 50Hz Battery : 12V NiMH Battery Battery Backup : 10hrs @ 5ml.hr Flow rate on 50ml Syringe Power Consumption : 7 VA Applicable Syringe : 5ml, 10ml, 20ml, 30ml, 50ml &100ml Syringes from JMS, Braun, Dispovan, BD and Custom Programmable for any Brand of Syringe. Automatic Syringe Detector : Available Custom Programmable Syringe : Available Flow Rate Range : 0.1 – 200 ml/Hr 70ml/Hr (5ml Syringe) 0.1 – 300 ml/Hr 110ml/Hr (10ml Syringe) 0.1 – 500 ml/Hr 190ml/Hr (20ml Syringe) 0.1 – 700 ml/Hr 260ml/Hr (30ml Syringe) 0.1 – 1200 ml/Hr 400ml/Hr (50ml Syringe) Infused Volume : 0.1 – 999.9 ml Elapsed Time : Display of Elapsed time from 00:01 to 99:59 Hrs Modes : Drug Library mode, Flow Rate only, Flow Rate & Target volume, Flow Rate & Target Time Target volume and target time Bolus : Purge Bolus & Auto Bolus Bolus Flow Rate : 10 – 200 ml/Hr 70 ml/Hr (5ml Syringe) 10 – 300 ml/Hr 110 ml/Hr (10ml Syringe) 10 – 500 ml/Hr 190 ml/Hr (20ml Syringe) 10 – 700 ml/Hr 260 ml/Hr (30ml Syringe) 10 – 1200 ml/Hr 400 ml/Hr (50ml Syringe) Bolus Volume : 0.1ml to 10 ml in 0.1 ml increments Dosage Taper Up/ Down(Sequential Mode) : Available with 10 different programs KVO : 0.1ml/Hr to 9.9ml/Hr in 0.1 ml increment Occlusion Pressure : 10 steps selection (OFF to 9 Levels) Alarms : tAr.1 – Target Volume reached tAr.2 – Target time reached End – End of Syringe occL – Occlusion OFF – Battery discharged AL 1 – Syringe holder disturbed during infusion AL 2 – Syringe Disengaged while running AL 3 – Motor unable to drive AL 4 – Mains to Battery F/R High reduce F/R 200 AL 5 – AC Power over limit AL 6 – AC Voltage below 215 AL 9 – Syringe not engage Audio/Visual Indication : Target reached (time or volume), End of syringe, Occlusion, Battery discharged, Motor unable to drive, Syringe not engaged, Near Empty, Battery low, Operation on mains / battery Display : Four 7 segment Display PCA (Optional) : PCA dose can be preset from 0.1 to 10ml. Minimum locking time interval between two doses, Time interval from 0 -24Hrs in steps of 1 min, Delivered and non delivered doses display Accuracy : Mechanical Accuracy ±1%; Including Syringe ± 3% Safety Testing : EN 60601-1, EN 60601-1-2, EN 60601-1-6, EN 60601-1-8, EN 60601-2-24 Certification : ISO 9001:2008; ISO 13485:2003; CE Dimension : 170 x 107 x 135 ( L x B x W) Space Occupied : 2.4 ltrs Weight : 1.75kg

products-and-services